Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · 2012 · 44 citations · 21 references
EngineeringBioengineeringBiomedical EngineeringBiomedical ImagingBiomedical OpticsBiophotonicsCellular ImagingOptical ImagingTerahertz PhotonicsTerahertz SpectroscopyFocal Plane ArraysQuantum Cascade LasersSignal-to-noise RatioSignal-to-noise Ratio AnalysisSignal-to-noise Ratio EnhancementTerahertz DetectionTerahertz ImagingTerahertz Quantum Cascade Lasers
This paper describes a real-time terahertz (THz) imaging system, using the combination of a palm-size THz camera with a compact quantum cascade laser (QCL). The THz camera contains a 320x240 microbolometer focal plane array which has nearly flat spectral response over a frequency range of ca. 1.5 to 100 THz, and operates at 30 Hz frame rate. The QCL is installed in compact cryogen-free cooler. A variety of QCLs are prepared which can cover frequency range from ca. 1.5 to 5 THz. THz images of biochemical samples will be presented, using the combined imaging system. Performance of the imaging system, such as signal-to-noise ratio of transmission-type THz microscope, is predicted.
21
Terahertz semiconductor-heterostructure laser
Rüdeger Köhler, Alessandro Tredicucci, Fabio Beltram et al. · Nature · 2002 · 2.7K citations
Velocity matching by pulse front tilting for large area THz-pulse generation
János Hebling, Gábor Almási, I. Z. Kozma et al. · Optics Express · 2002 · 847 citations · Full text