Concepedia

Publication | Open Access

Spatial variation in cartilage T2 of the knee

285

Citations

14

References

2001

Year

Abstract

Technical limitations imposed by resolution and B1 homogeneity have thus far limited quantitative in vivo T2 mapping of cartilage to the patella. The purpose of this study is to develop T2 mapping of the femoral/tibial joint and assess regional variability of cartilage T2 in the knee. Quantitative in vivo T2 mapping of the knee was performed on 15 asymptomatic adults (age, 22-44) using a 3T MR scanner. There is a consistent pattern of spatial variation in cartilage T2 with longer values near the articular surface. The greatest variation occurs in the patella, where T2 increases from 45.3 +/- 2.5 msec at a normalized distance of 0.33-67 +/- 5.5 msec at a distance of 1.0. These results demonstrate feasibility of performing in vivo T2 mapping of femoral tibial cartilage. Except for the superficial 15% where T2 values are lower, the spatial variation in T2 of femoral and tibial cartilage is similar to patellar cartilage.

References

YearCitations

1988

7.8K

1995

472

1992

394

2000

388

1997

327

1993

261

1997

168

1997

163

1994

140

1996

101

Page 1