A Comparison of the Steady-State Pharmacokinetics and Pharmacodynamics of a Novel Rapid-Acting Insulin Analog, Insulin Glulisine, and Regular Human Insulin in Healthy Volunteers Using the Euglycemic Clamp Technique
53
Citations
0
References
2005
Year
Molecular PharmacologyDiabetes ManagementInsulin ManagementDiabetesPharmacologyBlood Glucose MonitoringSteady-state PharmacokineticsDiabetes MellitusHyperglycemiaInsulin GlulisineEuglycemic Clamp TechniqueMetabolismMedicineInsulin Glulisine InfusionRegular Human Insulin
Insulin glulisine is a new rapid-acting insulin analog. The aim of this study was to assess the glucodynamic efficacy of insulin glulisine compared with regular human insulin (RHI) using a manual euglycemic clamp technique. Steady-state pharmacokinetics of insulin glulisine, and its cardiac safety (ECG) and tolerability after intravenous administration, were also determined. This was a single center, randomized, open-label, two-way crossover study in healthy male subjects (n = 16). At the treatment visits subjects received an intravenous infusion of the study drug at a rate of 0.8 mU kg (-1) . min (-1) for 2 hours. Individual baseline glucose concentrations were targeted for euglycaemia and maintained with a manual adjusted 20 % glucose solution over the clamp period of a maximum 6 hours. A glulisine-specific antibody was used to quantify glulisine concentrations by radioimmunoassay, while a non-specific insulin antibody and C-peptide based correction for endogenous insulin was used to estimate exogenous human insulin (RHI). At steady state (90 - 120 min), insulin glulisine and RHI had equivalent glucose utilization (GIR-AUC (SS), 209 [corrected] mg . kg (-1) for glulisine, 214 [corrected] mg . kg (-1) for RHI) and infusion rates (GIR (SS), 7.0 and 7.2 [corrected] mg . kg (-1) . [corrected] min (-1) . kg (-1)). Both insulins also presented equal total glucose disposal (GIR-AUC (0 - clamp end), 995 and 1050 [corrected] mg . kg (-1)) and onset of activity within 20 min. Insulin glulisine and RHI showed parallel time concentration profiles with similar distribution and elimination, but the different antibodies employed for radioimmunoassay impeded a quantitative comparison. There were no noteworthy individual or within-group changes in cardiac repolarisation parameters measured by 12-lead ECG during insulin glulisine infusion. In conclusion, insulin glulisine and RHI show similar distribution and elimination profiles and equivalent glucodynamic efficacy on a molar, unit-per-unit basis.