Physics in Medicine and Biology · 2003 · 123 citations · 15 references
MedicineRadiation OncologyRadiologyRadiation DosimetryRadiation MeasurementTreatment PlanningComputed TomographyComputed Tomography PhysicsDose CalibrationRadiation TherapyRadiation Treatment PlanningRadiobiological ModelingAccuracyCalibration Method ValidationComputerized Treatment PlanningCt Number To Electron Density CalibrationCt Number To Electron Density ConversionRadiation Dose EstimationRadiotherapy Dose PlanningTissue-equivalent Materials
A method to establish the relationship between CT number and effective density for therapeutic radiations is proposed. We approximated body tissues to mixtures of muscle, air, fat and bone. Consequently, the relationship can be calibrated only with a CT scan of their substitutes, for which we chose water, air, ethanol and potassium phosphate solution, respectively. With simple and specific corrections for non-equivalencies of the substitutes, a calibration accuracy of 1% will be achieved. We tested the calibration method with some biological materials to verify that the proposed method would offer the accuracy, simplicity and specificity required for a standard in radiotherapy treatment planning, in particular with heavy charged particles.