Electric field (E-field) in air gap streamer discharges under positive lightning impulse was measured by specifically developed integrated electro-optic sensors. An E-field step phenomenon was observed. The E-field firstly agreed with the Laplace field, then suddenly increased with a rise time of μs. The occurrence probability of this phenomenon increased as the applied voltage increased. The discharge current waveforms and photos taken by a fast camera prove the E-field step was caused by the space net charge. From the E-step rise time and the corona area range, the average electron drift speed under the experiment situation was estimated about 0.2 × 106 – 0.6× 106 m/s.