Concepedia

Publication | Open Access

Evaluation of droplet dispersion during non-invasive ventilation, oxygen therapy, nebuliser treatment and chest physiotherapy in clinical practice: implications for management of pandemic influenza and other airborne infections

246

Citations

0

References

2010

Year

Abstract

NIV and chest physiotherapy are droplet (not aerosol)-generating procedures, producing droplets of > 10 µm in size. Due to their large mass, most fall out on to local surfaces within 1 m. The only device producing an aerosol was the nebuliser and the output profile is consistent with nebuliser characteristics rather than dissemination of large droplets from patients. These findings suggest that health-care workers providing NIV and chest physiotherapy, working within 1 m of an infected patient should have a higher level of respiratory protection, but that infection control measures designed to limit aerosol spread may have less relevance for these procedures. These results may have infection control implications for other airborne infections, such as severe acute respiratory syndrome and tuberculosis, as well as for pandemic influenza infection.