IEEE Transactions on Power Electronics · 2013 · 148 citations · 19 references
EngineeringElectrical EngineeringFault ToleranceFault-tolerant SystemsPower ElectronicsDc-dc ConversionDc-dc ConvertersDiagnosisDiagnosticsFault DetectionFault DiagnosisCondition Monitoring Of Power ConvertersDc-dc Converter DiagnosticsFault Diagnosis In Power ConvertersImbalanceInterleaved Dc-dc ConverterOpen Circuit DiagnosisOpen-circuit Fault DetectionPower Electronics Fault Diagnosis
Interleaved dc-dc converters have been widely applied, because of their benefits related to efficiency, size, thermal management, modularity, and output current ripple cancellation. These converters present an enhanced fault tolerance capability, but an open-circuit fault can leads to ripple beyond load requirements. This paper presents a fault-diagnostic method for interleaved dc-dc converters using only the dc-link current derivative sign features. The dc-link current derivative is thoroughly studied for both healthy and faulty modes. Its sign variation during different time intervals defined by the number of switches in conduction mode contains important information for open-circuit fault detection. The presented method is robust to transients and current imbalance between phases and no additional sensors are required. A photovoltaic system application is presented to validate this method.
19
Power electronics converters, applications and design
F.V.P. Robinson · Microelectronics Journal · 1997 · 5.1K citations
Jorge O. Estima, António J. Marques Cardoso · IEEE Transactions on Industrial Electronics · 2012 · 373 citations
Engineering, Electrical Engineering, Diagnostic Reasoning +16