Proceedings of the IEEE · 2009 · 61 citations · 31 references
MedicineNuclear MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyComputed TomographyMedical Image FormationMedical ImagingMedical Imaging PhysicsPositron Emission TomographyRadiological AnatomyComputed Tomography PhantomsDiagnostic OncologyOrgan Motion ModelingPatient-specific ModelsPet AcquisitionPet QuantificationPet-computed TomographyTumor Volume Estimation
The purpose of the work described in this paper was the development of a framework for the creation of a realistic positron emission tomography (PET) simulated database incorporating patient-specific variability. The ground truth used was therefore based on clinical PET/computed tomography (CT) data of oncology patients. In the first step, the NURBS-based cardiac-torso phantom was adapted to the patient's CT acquisitions to reproduce their specific anatomy while the corresponding PET acquisitions were used to derive the activity distribution of each organ of interest. Secondly, realistic tumor shapes with homogeneous or heterogeneous activity distributions were modeled based on segmentation of the PET tumor volume and incorporated in the patient-specific models obtained at the first step. Lastly, patient-specific respiratory motion was also modeled. The derived patient-specific models were subsequently combined with the PET SORTEO Monte Carlo simulation tool for the simulation of the whole-body PET acquisition process. The accuracy of the simulated datasets was assessed in comparison to the original clinical patient images. In addition, a couple of applications for such simulated images were also demonstrated. Future work will focus on the creation of a comprehensive database of simulated raw data and reconstructed whole-body images, facilitating the rigorous evaluation of image-processing algorithms in PET for oncology applications.
31
GATE: a simulation toolkit for PET and SPECT
S Jan, G. Santin, D. Strul et al. · Physics in Medicine and Biology · 2004 · 2.1K citations · Full text
Computerized three‐dimensional segmented human anatomy
I. George Zubal, Charles R. Harrell, E. O’Brian Smith et al. · Medical Physics · 1994 · 1.1K citations
Correction for partial volume effects in PET: principle and validation.
Olivier Rousset, Yilong Ma, Alan C. Evans · PubMed · 1998 · 934 citations
Corinna Bürger, Gerhard W. Goerres, S. Schoenes et al. · European Journal of Nuclear Medicine and Molecular Imaging · 2002 · 425 citations