1973 · 10 citations · 0 references
EngineeringChemical EngineeringMechanical EngineeringFluid DynamicsHeat TransferReservoir EngineeringBoiling Heat TransferHeat ExchangersHeat FlowHeat PumpsHeat Transfer FundamentalsHeat Transfer In FluidsHeat Exchanger DesignHeat Exchanger PerformanceHeat Pipe TechnologyHeat PipesHeat Pump TechnologyHeat Transfer In PipesNitrogen Dioxide ControlTransport Capacity
The high-capacity, pressure-primed, tunnel-artery wick concept was used in a gas-controlled variable conductance heat pipe. A variety of techniques were employed to control the size of gas/vapor bubbles trapped within the artery. Successful operation was attained with a nominal 6-foot long, 1-inch diameter cold reservoir VCHP using ammonia working fluid and nitrogen control gas. The pipe contained a heat exchanger to subcool the liquid in the artery. Maximum transport capacity with a 46-inch effective length was 1200 watts level (more than 50,000 watt-inches) and 800 watts at 0.5-inch adverse tilt.