Safety profile of ultrasmall superparamagnetic iron oxide ferumoxtran‐10: Phase II clinical trial data

Raju Sharma, Sanjay Saini, Pablo R. Ros, P F Hahn, William Small, Eduard E. de Lange, Arthur E. Stillman, Robert R. Edelman, Val M. Runge, Eric K. Outwater,

Journal of Magnetic Resonance Imaging · 1999 · 51 citations · 6 references

Concepts

Abstract

The safety data from the phase II clinical trial of ferumoxtran-10, an ultrasmall superparamagnetic iron oxide contrast agent, are presented. One hundred and four patients with focal liver or spleen pathologies underwent ferumoxtran-10-enhanced magnetic resonance (MR) imaging at doses of 0.8, 1.1, and 1.7 mg Fe/kg. Overall, 15% patients reported a total of 33 adverse events, regardless of causality. The adverse events most frequently seen were dyspnea (3.8%), chest pain (2.9%), and rash (2.9%). No serious adverse events were reported during the 48 hour observation period. There were no clinically significant effects on vital signs, physical examination, and laboratory results. Ferumoxtran-10 is a safe and well tolerated MR contrast agent.

References

6