MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyContrast AgentsContrast MediaLiver ImagingMagnetic Resonance Contrast MechanismsMagnetic Resonance ImagingMagnetic Resonance Imaging PhysicsContrast Agent AdministrationContrast Agent SafetyContrast Agent ToxicityFocal Liver LesionsPhase Ii Clinical TrialsSafety In Magnetic Resonance ImagingSerious Adverse EventsSuperparamagnetic Contrast Agents
The safety data from the phase II clinical trial of ferumoxtran-10, an ultrasmall superparamagnetic iron oxide contrast agent, are presented. One hundred and four patients with focal liver or spleen pathologies underwent ferumoxtran-10-enhanced magnetic resonance (MR) imaging at doses of 0.8, 1.1, and 1.7 mg Fe/kg. Overall, 15% patients reported a total of 33 adverse events, regardless of causality. The adverse events most frequently seen were dyspnea (3.8%), chest pain (2.9%), and rash (2.9%). No serious adverse events were reported during the 48 hour observation period. There were no clinically significant effects on vital signs, physical examination, and laboratory results. Ferumoxtran-10 is a safe and well tolerated MR contrast agent.
6