The Journal of Strength and Conditioning Research · 2015 · 115 citations · 26 references
EducationKinesiologyExercise PhysiologyExercise TestingPhysical TherapyMuscle Strength AssessmentMuscle Strength TestingMuscular Strength TestingPhysical FitnessResistance TrainingStrength TrainingCriterion ValidityForce-time Curve AnalysisIsometric Muscle Strength TestingIsometric Strength TestingResistance Skills TrainingStrength Testing ReliabilityStrength Testing ValidityTest-retest Reliability
James, LP, Roberts, LA, Haff, GG, Kelly, VG, and Beckman, EM. Validity and reliability of a portable isometric mid-thigh clean pull. J Strength Cond Res 31(5): 1378-1386, 2017-This study investigated the test-retest reliability and criterion validity of force-time curve variables collected through a portable isometric mid-thigh clean pull (IMTP) device equipped with a single-axial load cell. Fifteen males with ≥6 months of resistance training experience attended two testing sessions. In each session, participants performed an IMTP in 2 separate conditions in a randomized counterbalanced manner. The criterion condition consisted of a closed-chain IMTP configured with a force plate (IMTPf), whereas the experimental test was undertaken using a portable IMTP with data acquired through a single-axial load cell (IMTPl). A very high reliability (coefficient of variation [CV] = 3.10, 90% confidence interval [CI]: 2.4-4.6%; intraclass correlation coefficient [ICC] = 0.96, 90% CI: 0.90-0.98) and acceptable validity (CV = 9.2, 90% CI: 7-14%; ICC = 0.88, 90% CI: 0.71-0.95) were found in the experimental condition for the measure of peak force. However, significant differences were present between the IMTPf and IMTPl (p < 0.0001). Alternate force-time curve variables did not reach acceptable levels of validity or reliability in the experimental condition. The IMTPl is a valid and highly reliable method for assessing peak force. This provides evidence supporting the use of an IMTPl as a cost-effective and portable alternative for those who wish to assess maximal force production in a similar fashion to a traditional IMTP. However, practitioners should be aware that these are slightly different tests.
26
Measures of Reliability in Sports Medicine and Science
Will G. Hopkins · Sports Medicine · 2000 · 4.5K citations
How to interpret changes in an athletic performance test
W. Wat Hopkins · Medical Entomology and Zoology · 2004 · 610 citations
The plantar sole is a ‘dynamometric map’ for human balance control
Anne Kavounoudias, R. Roll, Jean‐Pierre Roll · Neuroreport · 1998 · 520 citations
Sophia Nimphius · Strength and conditioning journal · 2012 · 424 citations