2002 · 11 citations · 4 references
EngineeringElectrical EngineeringCircuit TheoryMicroelectronicsPower ElectronicsConverter TopologiesElectromagnetic CompatibilityHigh-frequency Power ConversionNoise In Electronic DevicesPower Factor CorrectionPower QualityBoost Power Factor Correction ConvertersCapacitor PlacementElectromagnetic Interference ReductionFiltersHigh-frequency ConversionPower Converter Design
The paper presents the results of an experimental activity concerned with the development of a 600 W boost power factor corrector (PFC) complying with the EMC standards for conducted EMI in the 150 kHz-30 MHz range. In order to accomplish this task, different circuit design and layout solutions are taken into account and their effect on the conducted EMI behavior of the converter is experimentally evaluated. Common-mode and differential-mode switching noise, together with input filters' design and topology and with the PCB layout (in terms of track length and spacing, ground and shielding planes etc.) are the key aspects which have been analyzed. In particular, the paper reports the conducted EMI measurements for different filter capacitor placements and values, for different power switch drive circuits together with several other provisions which have turned out to be decisive in the reduction of the generated EMI.
4
Introduction to electromagnetic compatibility
Choice Reviews Online · 2006 · 2.4K citations
Introduction to electromagnetic compatibility
Choice Reviews Online · 1993 · 781 citations
Control techniques for power factor correction converters
L. Rossetto · 1994 · 181 citations