Clinical Chemistry · 1998 · 30 citations · 2 references
MedicineEndocrinologyGood Clinical PracticeGood Laboratory PracticeReproductive EndocrinologyAssay ValidationBioanalytical Method ValidationEndocrine AssessmentEndocrine TestingHormonal EvaluationImmunoassay AnalysisEstradiol AssayEstradiol LevelsEstradiol MeasurementHormone ImmunoassaysInterlaboratory Method ComparisonLaboratory Standardization In EndocrinologyReference Panel ConstructionStandardization
Standardization of immunoassays for estradiol-17β (E2) for accuracy was considered in the “Estradiol International Workshops” (1). There, industry asked our laboratory to provide them with a means to evaluate the accuracy/specificity of their E2 test systems. In answer to this demand, we developed and made commercially available an accuracy-based panel of patient specimens. The results of the method comparisons subsequently performed by industry are presented below. Perspectives to use this exercise as a basis for further international standardization efforts are given. The reference panel (tradename: SysRef E2) was prepared through a joint venture between our university laboratory and Scantibodies Laboratory, Inc. (SLI, Santee, CA). To allow a realistic evaluation of routine test systems, the panel consisted of sera from single donations and had E2 concentrations and matrices of clinical relevance: 5 sera were from men and 12 from women. The latter were either in the fertile stage of life, some of them at a defined stage of the menstrual cycle, or postmenopausal. For another five female sera, we deviated from the “single donation” approach by supplementing them with serum from a pregnant woman. This compromise was made because it was considered desirable to include sera with concentrations typical for ovulation-induction therapy, for which it was, unfortunately, not possible to obtain a sufficient volume of blood from such women. The study showed, however, that the samples did behave in the method comparison in an identical manner as the single-donation sera. All blood donations were allowed to clot for 1 h at room temperature and were separated by centrifugation. No preservatives were added. The resulting fresh sera (∼200 mL) were stored for 3 days at 4 °C, then sterile-filtered, placed in 1-mL aliquots in screw-capped EppendorfR cups, frozen, and stored at SLI at −70 °C. All donations were tested for infectious …
2
Linda M. Thienpont, Patrick G. Verhaeghe, K A Van Brussel et al. · Clinical Chemistry · 1988 · 52 citations