Effect of Testing Temperature on SSC Properties of Low Alloy Steel

Kenji Kobayashi, Tomohiko Omura, Masakatsu Ueda, Keiichi Nakamura

2006 · 28 citations · 6 references

Concepts

Abstract

Abstract Effects of test variables (testing temperature, solution type and specific solution volume) on KISSC values of low alloy steel were investigated by DCB tests. The decrease in testing temperature decreased the measured KISSC values due to the increase in absorbed-hydrogen contents into the DCB specimens. It is considered that the degree of hydrogen accumulation at crack tip areas in DCB specimens could be higher at low temperature than that at higher temperature. The scatter of KISSC values in conventional NACE solution A was large, although that in solution B was smaller, due to a difference in stability of solution pH. The increase in specific solution volume to test specimen surface area slightly decreased KISSC values due to an increase in the corrosion rate.

References

6