2006 · 28 citations · 6 references
Natural SciencesMaterials EngineeringMaterials ScienceCorrosion ScienceMetallic MaterialsMetallurgyCorrosion EngineeringCorrosion EvaluationCorrosion KineticsCorrosion Of SteelsCorrosion TestingSteel MaterialsCorrosion Rate ReductionLow Alloy SteelsLow-alloy SteelLow-alloy Steel CorrosionLow-temperature MaterialsTemperature Effects On Corrosion
Abstract Effects of test variables (testing temperature, solution type and specific solution volume) on KISSC values of low alloy steel were investigated by DCB tests. The decrease in testing temperature decreased the measured KISSC values due to the increase in absorbed-hydrogen contents into the DCB specimens. It is considered that the degree of hydrogen accumulation at crack tip areas in DCB specimens could be higher at low temperature than that at higher temperature. The scatter of KISSC values in conventional NACE solution A was large, although that in solution B was smaller, due to a difference in stability of solution pH. The increase in specific solution volume to test specimen surface area slightly decreased KISSC values due to an increase in the corrosion rate.
6
NACE TM0177 Method D Test Procedure (DCB) Learnings from Comparative Laboratory Testing
K. E. Szklarz, Pierre Sutter, Jean Leyer et al. · 2003 · 23 citations
Effect of Different Test Variables on the Kissc Value
HA Ernst, G. Echaniz, Richard E. Bravo et al. · 2004 · 17 citations
Natural Sciences, Materials Engineering, Materials Science +16
Specimen Geometry Effects on Crack Growth in Sour Environments
HA Ernst, Jose ́ A. Villasante, N. Pachao et al. · 2002 · 17 citations