Clinical Chemistry · 1983 · 20 citations · 0 references
PharmacyPharmaceutical AnalysisPharmacologyChromatographic AnalysisClinical BiochemistryTherapeutic Drug MonitoringBioanalytical Method ValidationChromatographic Analysis Of PharmaceuticalsChromatographyClinical AnalysisLiquid ChromatographyBioanalytical ChromatographyChromatographic BehaviorChromatographic InstrumentationCompressionInternal Standard AnalysisStandard Curve Construction
A "high-performance" liquid-chromatographic technique involving a radial compression module is used for measuring chloramphenicol and five cephalosporin antibiotics: cefotaxime, cefoxitin, cephapirin, and cefamandol. Serum proteins are precipitated with acetonitrile solution containing 4'-nitroacetanilide as the internal standard. The drugs are eluted with a mobile phase of methanol/acetate buffer (30/70 by vol), pH 5.5. Absorbance of the cephalosporins is monitored at 254 nm. Standard curves are linear to at least 100 mg/L. The absorbance of chloramphenicol is monitored at 254 nm and 280 nm, and its standard curve is linear to at least 50 mg/L. The elution times for various other drugs were also determined, to check for potential interferents.