Nigerian Journal of Technology · 2014 · 30 citations · 10 references
EngineeringCivil EngineeringMaterials EngineeringBuilding MaterialsSolid Waste ManagementWaste ManagementConcrete MaterialsConstruction Waste ManagementMaterial Waste ManagementMunicipal Solid Waste ManagementPlastic Waste ManagementWaste GenerationBulk DensityCompressive StrengthLightweight ConcretePlastic Waste RecoveryPolyethyleneReplacementSolid Waste Management SystemsWaste-derived Materials
This study evaluates an alternative solid waste management option for Low-Density Polyethylene (LDPE) waste commonly called bpure water sachetb as partial replacement of sand in concrete. Three mix ratios of 1:1:2, 1:1.5:3, 1:2:4 were used while the LDPE waste materials were obtained within University of Lagos campus, in Lagos State of Nigeria. The pulverized LDPE plastic waste, with compacted and uncompacted bulk densities of 362.9 kg/m3 and 403.23 kg/m3 respectively, could be classified as an ultra-lightweight fine aggregate in terms of bulk density. The bulk density of the plastic concretes produced using 1:1:2, 1:1.5:3 and 1:2:4 range between 2417.78-2548 kg/m3, 2348.63-2589.63 kg/m3, 2429.63-2424.6 kg/m3 respectively with corresponding compressive strengths range of 22.64-34.26, 20.47-27.32 and 20.21-27.47 N/mm2 and could be classified as normal-weight concrete which meets the minimum compressive strength for use as lightweight aggregate in plain concrete (7N/mm2). The optimum and preferable mix is 1:1:2.http://dx.doi.org/10.4314/njt.v33i4.1
10
Guide for Structural Lightweight Aggregate Concrete
ACI Committee · ACI Journal Proceedings · 1967 · 326 citations