Procedia Engineering · 2015 · 17 citations · 1 references
ArchitectureArchitectural EngineeringBuilding ScienceBuilding PhysicsHeat TransferThermal ComfortBuilding Cooling SystemsBuilding Thermal PerformanceHeat Transfer In BuildingsThermal Comfort DesignThermal PerformanceThermal Performance AssessmentAir Temperature MeasurementApartment ArchitectureNaturally Ventilated Building ComfortPassive Cooling SystemsSurface TemperatureSurface Temperature AnalysisThermal Comfort EvaluationThermal Environment Assessment
This study aims to investigate the detailed thermal environments in apartments of Surabaya, Indonesia and discuss their potential passive cooling strategies. Major thermal parameters, vertical distribution of air temperature and surface temperature of walls/ceiling were measured in one of the representative units of three types of apartments respectively, under different natural ventilation conditions. The results revealed that the unit in the old public apartment showed better thermal environments compared to those in the other two apartments. It is very difficult to achieve thermal comfort during most of the day particularly in the new public and private apartments by means of natural ventilation alone. Building orientation, insufficient shading devices, and building materials are some of the factors causing hot conditions particularly in the newly emerging middle-class apartments. Several passive cooling strategies were proposed based on the measurement results.
1
Doris Hooi Chyee Toe, Tetsu Kubota · Frontiers of Architectural Research · 2013 · 183 citations · Full text
Architecture, Architectural Engineering, Building Science +16