Pseudoaneurysm formation after flexible ureterorenoscopy and electrohydraulic lithotripsy

William Aston, R. Whiting, Matthew Bultitude, Ben Challacombe, Jonathan Glass, Prokar Dasgupta

International Journal of Clinical Practice · 2004 · 18 citations · 3 references

Concepts

Abstract

Although electrohydraulic lithotripsy (EHL) is regularly used to fragment urinary calculi, it has the potential to cause significant renal tract damage. We report a complication of EHL use during flexible ureterorenoscopy, where recovery was complicated by delayed, prolonged haematuria secondary to the formation of a pseudoaneurysm in an interlobar renal artery. Embolisation was achieved by the insertion of a coil.

References

3