MedicineOphthalmologyVision ScienceContrast SensitivityOcular DiseaseVisual PerceptionCataract AssessmentCataract EvaluationPeripheral Contrast SensitivityVisual AcuityVisual Field AssessmentVisual ImpairmentAcuity DeficitsAcuity In CataractAcuity MeasurementReduced Visual AcuitySenile CataractUncorrected Visual AcuityVisual Acuity ThresholdsVisual Impairment Due To Cataract
Contrast thresholds for a range of different spatial frequencies were compared with "acuity" tests for 10 subjects with uniocular senile cataract. The results indicate that the magnitude and extent of the intra-resolution limit abnormality vary dramatically in cataract subjects and that, for some subjects, vision is abnormal for objects of all sizes. This finding indicates that the present acuity evaluation of vision with cataracts is inadequate because, in some cases, it grossly overestimates the nature of the visual world of the cataract patient.
5
Optical and retinal factors affecting visual resolution.
F. W. Campbell, D G Green · The Journal of Physiology · 1965 · 1.6K citations
Laboratory Evaluation of a Clinical Glare Tester
David M. Miller, M.E. Jernigan, Slavko Molnar et al. · Archives of Ophthalmology · 1972 · 44 citations
Degradation of vision through a simulated cataract.
J. L. Zuckerman, David Miller, W. A. Dyes et al. · PubMed · 1973 · 33 citations