DergiPark (Istanbul University) · 2002 · 12 citations · 0 references
Open access
Natural SciencesChemistryAnalytical ChemistryElectroanalytical MethodsInorganic ChemistryExtraction TechniquesInstrumental AnalysisBismuth AbsorptionCopper AlloysDetection Limit AssessmentExtractionsInstrument Detection LimitMethod Detection LimitSpeciation In Water Samples
Bismuth(III) (0-25 m g/ml) is determined spectrophotometricaly at 513 nm after extraction into dichloromethane of the ion associate di-(hydrogenatedtallowalkyl)dimethylammonium tetraiodobismuthate. The reagent stream is distilled water, merged with 1.0 M sulfuric acid, 5% potassium iodide and 5% (w/v) ascorbic acid solution. The reagent stream is 0.2% (w/v) di-(hydrogenatedtallowalkyl)dimethylammonium chloride solution. The injection rate is 15 h-1. The calibration graph is linear up to 25 m g/ml. The detection limit is 0.35 m g/ml Bi. The system is applied on water samples and copper-based alloys.