PubMed · 1996 · 13 citations · 0 references
Natural SciencesMaterials ScienceBiomechanicsMechanical Behavior Of MaterialsStructural EngineeringAbutment DesignBridge LoadsForce Application MechanicsImplant BiomechanicsImplant DesignStructural LoadsBiomechanical Testing Of ImplantsBiomechanics Of Implant-supported OverdenturesForce DistributionForce TransmissionForce Transmission SystemsImplant Fixture DesignImplant Material MechanicsTransducers
This study investigated force transmission in an implant supported bridge with varying degrees of fit. The project utilised an in vitro model of five implant fixtures mounted linearly and rigidly. These supported a well-fitting cast gold superstructure via implant abutments fitted with strain gauges so as to function as force transducers. Gaps of 10-110 microns were created at the middle and one terminal abutment and loads of 50N applied over the cantilever and 230N between the terminal abutments. Force distribution was uneven, compression, tension and torque observed, and loading of the cantilever noted to generate large forces.