Canadian Journal of Civil Engineering · 2010 · 17 citations · 18 references
EngineeringChemical EngineeringEnvironmental EngineeringResource RecoveryWastewater TreatmentWater TreatmentAnaerobic DigestionNutrient RecoveryNutrient RemovalResource Recovery From WastewaterSludge Resource RecoverySludge TreatmentAnaerobic Co-digestionAnaerobic Digestion Nutrient RecoveryCarbon DioxideCarbon Dioxide StrippingCarbon RemovalCrystallizationProcess Optimization In Anaerobic DigestionSludge Recirculation
The feasibility of stripping CO 2 from anaerobic digester centrate (generated in a sludge dewatering process) to raise pH, and therefore reduce the cost of caustic chemical(s) dosage for similar operation in a struvite-recovery system, was investigated. A cascade CO 2 stripper was installed in a pilot-scale, struvite-recovery reactor system at the Lulu Island Wastewater Treatment Plant, Richmond, British Columbia, Canada, as a replacement of part of (about 1/3) the reactor downpipe. Centrate was used as the process feed. Both the influent and the effluent from the struvite reactor were analyzed for pH, temperature (°C), and concentrations of Mg, NH 4 -N, and PO 4 -P. Results indicated that, by adding the CO 2 stripper, caustic chemical savings was as much as 46%–65%. Moreover, because of the capability of the stripper in providing a more gradual pH increase, fewer fine solids were produced in the reactor than when caustic solution was used to raise the pH of the reactor.
18
Potential phosphorus recovery by struvite formation
Yousuf Dar Jaffer, T. Clark, P. Pearce et al. · Water Research · 2002 · 471 citations
Predicting struvite formation in digestion
Kurt Ohlinger, Thomas M. Young, Edward D. Schroeder · Water Research · 1998 · 382 citations