Use of carbon dioxide stripping for struvite crystallization to save caustic dosage: performance at pilotscale operationPaper submitted to the Journal of Environmental Engineering and Science.

Kazi Parvez Fattah, Y. Zhang, D. S. Mavinic, Frank-Thomas Koch

Canadian Journal of Civil Engineering · 2010 · 17 citations · 18 references

Concepts

Abstract

The feasibility of stripping CO 2 from anaerobic digester centrate (generated in a sludge dewatering process) to raise pH, and therefore reduce the cost of caustic chemical(s) dosage for similar operation in a struvite-recovery system, was investigated. A cascade CO 2 stripper was installed in a pilot-scale, struvite-recovery reactor system at the Lulu Island Wastewater Treatment Plant, Richmond, British Columbia, Canada, as a replacement of part of (about 1/3) the reactor downpipe. Centrate was used as the process feed. Both the influent and the effluent from the struvite reactor were analyzed for pH, temperature (°C), and concentrations of Mg, NH 4 -N, and PO 4 -P. Results indicated that, by adding the CO 2 stripper, caustic chemical savings was as much as 46%–65%. Moreover, because of the capability of the stripper in providing a more gradual pH increase, fewer fine solids were produced in the reactor than when caustic solution was used to raise the pH of the reactor.