Journal of Laparoendoscopic & Advanced Surgical Techniques · 2014 · 15 citations · 10 references
MedicinePerioperative MedicineSurgeryLaparoscopic UrologyUrologic SurgeryVentilationAnesthesia For Urologic SurgeryLaparoscopic Renal SurgeryLung-protective VentilationMechanical VentilationPositive End-expiratory PressureVolume-control VentilationArterial Blood Gas MonitoringExtubation TimingLaparoscopic Urologic SurgeryProtective Ventilation During SurgerySurgical UrologyTidal Volume SelectionTidal Volume SettingsVentilatory Support Settings
BACKGROUND: To study the effects of low tidal volume with positive end-expiratory pressure (PEEP) on arterial blood gases of patients undergoing laparoscopic urologic surgeries. SUBJECTS AND METHODS: Eighty-six laparoscopic urologic patients were enrolled in this study. Patients were randomized into two groups according to the ventilatory settings. In the conventional group (Group C) (n=43), the tidal volume was 10 mL/kg, and the PEEP was set at 0 cm of H2O. In the low tidal volume with PEEP group (Group LP), the tidal volume was 6 mL/kg, with PEEP of 5 cm of H2O. In both groups total minute volume was 6 L/kg. Peak and plateau airway pressure (PPEAK and PPLAT, respectively) and arterial blood gases were recorded before pneumoperitoneum (PNP) (T1) and the first and third hour (T3) after PNP induction and also after extubation in the intensive care unit. Additionally, heart rate, mean arterial pressure, and peripheral O2 saturation of hemoglobin were recorded. RESULTS: Heart rate, PPEAK, and PPLAT values were similar in both groups. Partial arterial O2 pressure values measured postoperatively were significantly higher in Group LP, whereas those measured before PNP induction were similar (P=.014 and P=.056, respectively). Compared with the baseline, partial arterial CO2 pressure values measured at T1 and at T3 after PNP induction were significantly higher in Group C than in Group LP (P<.001). The pH values of Group C at T1 and at T3 postoperatively were significantly lower than the values of Group LP (P<.001). Extubation times were significantly lower in Group LP. CONCLUSIONS: The results of the present study suggest that low tidal volume with PEEP application may be a good alternative for preventing high CO2 levels and yielding better oxygenation and lower extubation times in patients undergoing prolonged laparoscopic urology.
10
Rogier M. Determann, A. A. N. M. Royakkers, Esther K. Wolthuis et al. · Critical Care · 2010 · 503 citations · Full text
Goda Choi, Esther K. Wolthuis, Paul Bresser et al. · Anesthesiology · 2006 · 207 citations · Full text
Health Professions, Clinical Sciences, Respiratory Therapy +16