A comparison of results for cholesterol in human serum obtained by the Reference Method and by the Definitive Method of the National Reference System for cholesterol.

P. Ellerbe, Gary L. Myers, G R Cooper, Harry S. Hertz, Lorna T. Sniegoski, Michael J. Welch, Edward White

PubMed · 1990 · 36 citations · 3 references

Concepts

Abstract

Here we compare the Reference Method (I) and the Definitive Method (II) for measurement of cholesterol in serum. For pure cholesterol solutions, values by I agree with values by II, but for fresh, frozen, or lyophilized sera, values by I average 1.6% higher than values by II. We conclude that an undetected interference is associated with I. However, the observed difference does not diminish the usefulness of I as an accuracy base for cholesterol measurements, because it is clinically insignificant at present.

References