The Journal of the Acoustical Society of America · 2015 · 148 citations · 29 references
Veterinary MedicineBiomedical EngineeringDiagnostic ImagingUltrasonographyUltrasoundAcoustic ImagingDiagnostic UltrasonographyUltrasonicsUltrasound ImagingUltrasound In OncologyUltrasound PhysicsOncolytic Viral TherapyPassive Acoustic LocalizationPassive Acoustic MonitoringReal-time Three-dimensional ImagingUltrasonic ImagingUltrasonic SensorsUltrasound TherapyUltrasound-guided Therapy
Passive acoustic mapping (PAM) enables real‑time three‑dimensional monitoring of ultrasound therapy by reconstructing acoustic emissions passively received on an array of ultrasonic sensors. The study presents a passive beamforming method that markedly improves spatial accuracy compared to the conventional time‑exposure acoustics (TEA) PAM reconstruction algorithm. The authors employ Capon and robust Capon beamformers to reduce interference artifacts and enhance resolution in PAM. Simulations and experiments show that bubble interactions cause artifacts that TEA cannot mitigate, whereas Capon‑based beamforming—especially the robust Capon variant—effectively reduces these artifacts and yields more accurate acoustic localization in both in vitro and in vivo oncolytic viral therapy trials.
Passive acoustic mapping (PAM) is a promising imaging method that enables real-time three-dimensional monitoring of ultrasound therapy through the reconstruction of acoustic emissions passively received on an array of ultrasonic sensors. A passive beamforming method is presented that provides greatly improved spatial accuracy over the conventionally used time exposure acoustics (TEA) PAM reconstruction algorithm. Both the Capon beamformer and the robust Capon beamformer (RCB) for PAM are suggested as methods to reduce interference artifacts and improve resolution, which has been one of the experimental issues previously observed with TEA. Simulation results that replicate the experimental artifacts are shown to suggest that bubble interactions are the chief cause. Analysis is provided to show that these multiple bubble artifacts are generally not reduced by TEA, while Capon-based methods are able to reduce the artifacts. This is followed by experimental results from in vitro experiments and in vivo oncolytic viral therapy trials that show improved results in PAM, where RCB is able to more accurately localize the acoustic activity than TEA.
29
High-resolution frequency-wavenumber spectrum analysis
J. Capon · Proceedings of the IEEE · 1969 · 6.2K citations