Orthodontics and Craniofacial Research · 2012 · 10 citations · 25 references
DentistryDental Materials ScienceOrthodonticsDental MaterialsPolymer EngineeringPolymerization Of Dental ResinsDental PolymersDual-cured Resin PolymerizationLight-cured Resin PolymerizationOrthodontic MaterialsPolymerization StressPolymerization Temperature EffectsAdhesive PolymerizationBond StrengthDegree Of Polymerization MonitoringDifferential CalorimetryDual-cure Polymerization DynamicsLight-cured Dental ResinsLight-curing EfficiencyThermodynamics Of Acid-base Reactions
OBJECTIVES: The polymerization and acid-base reactions in resin-modified glass-ionomers (RMGI) are thought to compete with and inhibit one another. To examine the effect of visible light-cure (VLC) delay on the polymerization efficiency and orthodontic bond strength of a dual-cured RMGI. SETTING AND SAMPLE POPULATION: The Orthodontics Graduate Program at Marquette University. An in vitro study utilizing 72 freshly extracted human bicuspid teeth. MATERIALS AND METHODS: A RMGI light-cured immediately, 2.5, 5, or 10 min after mixing comprised the experimental groups. Isothermal and dynamic temperature scan differential scanning calorimetry (DSC) analysis of the RMGI was performed to determine extents of VLC polymerization and acid-base reaction exotherms. Human premolars (n = 18/group) were bonded with the RMGI. Shear bond strength and adhesive remnant index (ARI) scores were determined. RESULTS: Differential scanning calorimetry results showed the 10-min-delay RMGI group experienced significantly (p < 0.05) lower VLC polymerization compared with the other groups. Acid-base reaction exotherms were undetected in all groups except the 10-min delay group. No significant differences (p > 0.05) were noted among the groups for mean shear bond strength. A chi-square test showed no significant difference (p = 0.428) in ARI scores between groups. CONCLUSIONS: Delay in light-curing may reduce polymerization efficiency and alter the structure of the RMGI, but orthodontic shear bond strength does not appear to be compromised.
25
A new translucent cement for dentistry. The glass ionomer cement
A.D. Wilson, B. E. Kent · BDJ · 1972 · 893 citations
Intra-oral temperature variation over 24 hours
Robert N. Moore · European Journal of Orthodontics · 1999 · 153 citations · Full text
Resin-modified Glass-ionomer Setting Reaction Competition
David W. Berzins, S. Abey, Marius C. Costache et al. · Journal of Dental Research · 2009 · 129 citations · Full text
Natural Sciences, Materials Engineering, Materials Science +15