Kinematics of the wrist. I. An experimental study of radial-ulnar deviation and flexion-extension.

Youngil Youm, R Y McMurthy, Adrian E. Flatt, T E Gillespie

Journal of Bone and Joint Surgery · 1978 · 602 citations · 0 references

Concepts

TL;DR

The wrist’s kinematics during radial‑ulnar deviation and flexion‑extension were investigated using multiple approaches. Six fresh cadaver wrists were examined with the forearm fixed in pronation, metal markers on metacarpals and carpal bones, and roentgenographic imaging to analyze radial‑ulnar deviation and flexion‑extension; similar roentgenographic and LED‑tracking studies were conducted on six volunteers and on 100 normal wrists. The analyses showed that wrist motion occurs about a fixed axis in the capitate head that does not change with hand position; the carpal height measured along the third metacarpal axis remains constant during radial‑ulnar deviation and can indicate carpal collapse; and the perpendicular distance from the fixed rotation axis to the ulna’s longitudinal axis quantifies carpal translation in pathological conditions.

Abstract

The kinematics of the wrist during radial-ulnar deviation and flexion-extension were studied in several ways. In six fresh cadaver wrists, the forearm was fixed in full pronation, each motion was constrained to one plane, and two metal markers were placed in each of the finger metacarpals, as well as in the radius and all of the carpal bones except the pisiform and greater multangular. Radial ulnar and flexion-extension movements in these wrists were studied roentgenographically. In the wrists of six normal volunteers, a similar roentgenographic analysis was carried out and the trajectories of wrist motions also were studied using light-emitting diodes. Finally, roentgenographic measurements were made on 100 wrists of normal subjects. From these studies, it was concluded that: (1) during each of these motions, rotation occurs about a fixed axis located within the head of the capitate, and the location of each axis is not changed by the position of the hand in either plane; (2) the distance from the base of the third metacarpal to the distal articular surface of the radius (the carpal height), measured along the proximally projected axis of the third metacarpal on posteroanterior roentgenograms, is constant throughout radial-ulnar deviation of the normal wrist and can be used as a measure of carpal collapse; and (3) the perpendicular distance of the fixed axis of rotation for radial-ulnar deviation from the distally projected longitudinal axis of the ulna can be used as a quantitative measurement of the amount of translation of the carpus in pathological conditions.