Acta Anaesthesiologica Scandinavica · 2012 · 38 citations · 32 references
Health ProfessionsClinical SciencesPulmonary Function TestingPulmonologyVentilationContinuous Positive Airway PressureLung VolumesMechanical VentilationPositive End-expiratory PressurePulmonary Function AssessmentPulmonary MechanicsChest Wall MechanicsLung ComplianceLung ElastanceLung Volume QuantificationPeep-pressure-volume RelationshipPressure-volume CurvesPulmonary ElastanceRespiratory System Elastance
INTRODUCTION: The aim of the present study was to demonstrate that lung elastance and transpulmonary pressure can be determined without using oesophageal pressure measurements. METHODS: Studies were performed on 13 anesthetized and sacrificed ex vivo pigs. Tracheal and oesophageal pressures were measured and changes in end-expiratory lung volume (ΔEELV) determined by spirometry as the cumulative inspiratory-expiratory tidal volume difference. Studies were performed with different end-expiratory pressure steps [change in end-expiratory airway pressure (ΔPEEP)], body positions and with abdominal load. RESULTS: A PEEP increase results in a multi-breath build-up of end-expiratory lung volume. End-expiratory oesophageal pressure did not increase further after the first expiration, constituting half of the change in ΔEELV following a PEEP increase, even though end-expiratory volume continued to increase. This resulted in a successive left shift of the chest wall pressure-volume curve. Even at a PEEP of 12 cmH(2) O did the end-expiratory oesophageal (pleural) pressure remain negative. CONCLUSIONS: A PEEP increase resulted in a less than expected increase in end-expiratory oesophageal pressure, indicating that the chest wall and abdomen gradually can accommodate changes in lung volume. The rib cage end-expiratory spring-out force stretches the diaphragm and prevents the lung from being compressed by abdominal pressure. The increase in transpulmonary pressure following a PEEP increase was closely related to the increase in PEEP, indicating that lung compliance can be calculated from the ratio of the change in end-expiratory lung volume and the change in PEEP, ΔEELV/ΔPEEP.
32
A simple method for assessing the validity of the esophageal balloon technique.
Ahmet Baydur, P. K. Behrakis, Walter A. Zin et al. · PubMed · 1982 · 1.1K citations
Effects of Anesthesia and Paralysis on Diaphragmatic Mechanics in Man
Alison B. Froese, A. C. Bryan · Anesthesiology · 1974 · 797 citations · Full text
Medicine, Anatomy, Anesthesiology +12
Luciano Gattinoni, Paolo Pelosi, Stefania Crotti et al. · American Journal of Respiratory and Critical Care Medicine · 1995 · 581 citations