Journal of Synchrotron Radiation · 2015 · 53 citations · 15 references
Veterinary MedicineRadiologyBiomedical ImagingDiagnostic ImagingDiagnostic RadiologyComputed TomographyContrast RadiographyRadiographic ImagingX-ray DetectionX-ray OpticsHigh-resolution X-ray ImagingPhase ImagingPhase-contrast ImagingReal-time Contrast ImagingReal-time ImagingX-ray Beamline OpticsX-ray Imaging PhysicsX-ray Imaging Systems
A full-field hard X-ray imaging beamline (BL-4) was designed, developed, installed and commissioned recently at the Indus-2 synchrotron radiation source at RRCAT, Indore, India. The bending-magnet beamline is operated in monochromatic and white beam mode. A variety of imaging techniques are implemented such as high-resolution radiography, propagation- and analyzer-based phase contrast imaging, real-time imaging, absorption and phase contrast tomography etc. First experiments on propagation-based phase contrast imaging and micro-tomography are reported.
15
Investigating microbial micro-habitat structure using X-ray computed tomography
Naoise Nunan, Karl Ritz, Mark L. Rivers et al. · Geoderma · 2005 · 132 citations