PubMed · 1997 · 65 citations · 17 references
MedicineNuclear MedicineRadiologyCardiac Nuclear MedicineDiagnostic ImagingDiagnostic RadiologyCardiac ImagingCardiac Nuclear ImagingCardiovascular ImagingMagnetic Resonance ImagingMedical ImagingPlanar ScintigraphyCardiac Chamber VolumesContour SegmentationFirst-pass Radionuclide AngiographyGated Blood Pool ImagingRight Ventricular ImagingSimpson's RuleVentricular Ejection Fraction AssessmentVisual Inspection
UNLABELLED: Tomographic techniques separate overlying structures, permitting measurements of absolute ventricular volumes. The purpose of this study was to determine absolute right and left ventricular volume and ejection fraction measurements with tomographic gated equilibrium blood-pool scintigraphy (TMUGA) compared to MRI and conventional planar scintigraphy. METHODS: Eighteen patients were studied. Ventricular volumes for TMUGA and MRI were calculated by modified Simpson's rule. TMUGA regions were defined by constraints including phase analysis, intensity threshold and visual inspection. MRI studies were acquired with a fast gradient-echo, ECG-gated, breath-hold technique and boundaries were defined by a semiautomated contour method. Conventional gated first-pass radionuclide angiography (FP) and planar gated equilibrium blood-pool scintigraphy (PMUGA) were performed for RV EF and LV EF, respectively. RESULTS: TMUGA absolute right ventricular volumes showed excellent-correlation with MRI for both right ventricular volumes (r = 0.91, slope = 0.90, s.e.e. = 15.7) and left ventricular volumes (r = 0.96, slope = 0.88, s.e.e. = 18.2). For left ventricular ejection fraction, TMUGA also showed excellent correlation with MRI (r = 0.94, slope = 1.10, s.e.e. = 9.0) and planar MUGA (r = 0.97, slope = 1.23, s.e.e. = 6.2). For right ventricular ejection fraction, TMUGA showed good correlation with both MRI (r = 0.88, slope = 0.79, s.e.e. = 6.0) and first-pass planar scintigraphy (r = 0.86, slope = 1.2, s.e.e. = 7.9). CONCLUSION: Tomographic gated blood-pool scintigraphy absolute right and left ventricular volumes and ejection fractions show good correlation with accepted techniques. Further studies are necessary to define the reproducibility of this method.
17
Measurement of right and left ventricular volumes in healthy individuals with cine MR imaging.
Udo Sechtem, P W Pflugfelder, Robert G. Gould et al. · Radiology · 1987 · 409 citations
Medicine, Cardiology, Radiology +17
Marvin A. Konstam, Marvin W. Kronenberg, Michel F. Rousseau et al. · Circulation · 1993 · 316 citations
Medicine, Cardiology, Pharmacology +17
Precision of measurements of right and left ventricular volume by cine computed tomography.
S J Reiter, John A. Rumberger, Andrew J. Feiring et al. · Circulation · 1986 · 166 citations · Full text
Medicine, Cardiology, Radiology +14