Shielding studies on a total-body neutron activation facility

Seyyed Hashem Miri Hakimabad, Hamed Panjeh, A Vojdani Noghreian

Iranian Journal of radiation research/Iranian journal of radiation research · 2007 · 12 citations · 4 references

Concepts

Abstract

Determination of elemental compositions for a human body is one of the useful tools for understanding general physiology relationships, diagnosing some disease and cancers, radiotherapy treatments, nutritional disorders, planning treatments for those same diseases and disorders and in quantifying the efficacy of some medicinal therapies. Therefore, a lot of techniques have been used to determine the precise amount of body chemical compositions. Use of neutrons is an ideal approach for conducting these measurements which can be used in three different forms; fast neutron analysis (FNA), prompt gamma neutron activation analysis (PGNAA), and delayed gamma neutron activation analysis (NAA). Prompt gamma neutron activation analysis technique is a powerful elemental analysis method (1). PGNAA has a wide range of applications, such as bulk material analysis and oil well logging, hidden or buried explosive materials detection (2-4). This method is based on the simple excitation and de-excitation of atom by absorbing a neutron followed by emitting a high-energy (multiMeV) prompt gamma ray. There are several prompt gamma rays with various intensions for a special active element (5). Ordinarily, the most intensive gamma ray in the spectrum is a characteristic sign for each element. So a gamma spectrum of an active sample can be assumed as a footprint of the existence of special elements in the sample. Since most of nuclei show an increasing in the neutron absorption cross section as the neutron energy decreases, PGNAA is a useful technique when using neutrons with low or thermal energy. Radioisotope Cf and Am-Be are neutron sources used for many applications in which compact, portable and reliable neutron sources are required. They are commonly used in the PGNAA method. They Background: Prompt gamma neutron activation analysis (PGNAA) is known as a non-invasive technique capable of measuring elemental concentration in voluminous samples in a short period of time. Also it is a valuable diagnostic tool for total body elemental measurements. Cf and Am-Be sources which are usually used in this method, generate not only neutrons, but also emit high-energy and unwanted gamma-rays. Because the patient must be located against the neutron source, patient dose during an analysis is an important concern when using this technique. Materials and Methods: Gamma-rays were attenuated without losing the neutron flux or significant alteration in the neutron spectrum. A relatively safe body chemical composition analyzer was designed with an optimal spherical gamma-ray shield, enclosed to the neutron source. Effects of gamma-ray shielding and optimum radius of spherical Pb shield was investigated and compared with the unfiltered bare source, using MCNP4C code. Then, the gamma ray dose equivalent per source neutron rate (user defined parameter) in the soft tissue is calculated for different radiuses of spherical Pb shield, for both neutron sources. Results: A decreasing flux of gamma-ray was observed when the radius of the spherical Pb shields increased. The value of this reduction was about 94% for Cf source when a lead spherical shield of radius 4 cm was used; while the reduction was about 50% for Am-Be source with the same spherical shield. For a spherical Pb shield of radius 4 cm, reduction of the gamma dose equivalent per source neutron rate was about 8.44|¤|10-17 Sv when the neutron source was Cf and about 1.24|¤|10-16 Sv when the neutron source was Am-Be. Conclusion: Results show using optimum gamma-ray shield geometry can reduce the patient absorbed dose per incident neutron in a body chemical composition analyzer. Iran. J. Radiat. Res., 2007; 5 (1): 45-51

References

4