Electrode Configurations for Resistivity Measurements on Concrete

W. J. McCarter, Gerry Starrs, Sivakumar Kandasami, Malcolm Chrisp

ACI Materials Journal · 2009 · 49 citations · 0 references

Concepts

Abstract

In this study, two- and four-electrode arrangements were used to evaluate the electrical resistance (hence resistivity) of saturated concrete specimens using both embedded rod-electrodes, external plate-electrodes, and combinations thereof Measurements were obtained mainly at a fixed frequency of 1 kHz. It is shown that the two-electrode external plate measurement system gave higher resistivity values than the four-electrode system; however studying the electrical response in terms of complex impedance, over the frequency range 1 to 10 MHz, revealed that the sponge-contacting system used in the two-electrode method introduced a spurious resistance attributed to the sponge-sample interface.