Cardiac blood-pool scintigraphy in rats and hamsters: comparison of five radiopharmaceuticals and three pinhole collimator apertures.
19
Citations
0
References
1991
Year
Pinhole Collimator AperturesDiastolic FunctionPositron Emission TomographyRadiopharmaceutical Therapy99Mtc-human Serum AlbuminBlood Flow MeasurementCardiac Blood-pool ScintigraphyCardiologyNuclear MedicineRadiologyHealth SciencesCardiovascular ImagingVascular ImageMedical ImagingPharmacologyPinhole AperturesPhysiologyRadiopharmaceuticalsCardiac DrugsCardiovascular PhysiologyMedicine
Preclinical evaluation of cardiac drugs may require evaluation of cardiac function in intact animals. To optimize the quality of radionuclide measurements of ventricular function in small animals, a comparison was made of gated blood-pool scans recorded with five blood-pool radiopharmaceuticals (99mTc-labeled human polyclonal IgG, 99mTc-human serum albumin labeled by two methods, and red blood cells radiolabeled with 99mTc via in vivo and in vitro methods) in rats and three pinhole apertures in hamsters. The quality of the radiopharmaceuticals was evaluated by comparing count density ratios (LV/BACKGROUND and LV/LIVER) and ejection fractions recorded with each agent. The edge definition of the left ventricle and count rate performance of the 1-, 2-, and 3-mm apertures was evaluated in hamsters. In general, the images obtained with the radiolabeled cells were superior to those obtained with the labeled proteins and no significant differences between the protein preparations were detected. Left ventricular ejection fractions calculated with all five radiopharmaceuticals were not significantly different. The best quality images were obtained with the 1-mm pinhole collimator. Ejection fraction and acquisition time were inversely related to aperture size. A good compromise between resolution and sensitivity was obtained with the 2-mm pinhole collimator.