Publication | Open Access
Passive proton therapy vs. IMRT planning study with focal boost for prostate cancer
15
Citations
22
References
2015
Year
Protons delivered comparable doses to targets in dose homogeneity and conformity and spared normal tissues from intermediate-to-low doses better than IMRT did. Further improvement of dose sparing and changes in homogeneity and conformity may be achieved by reducing proton range uncertainties and from implementing intensity modulation.