2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · 2005 · 11 citations · 6 references
EngineeringElectrical EngineeringAnalog ElectronicsCircuit TheoryPower ElectronicsActive FiltersDc-dc ConversionDc-dc ConvertersDistortion AnalysisPower QualityVoltage RegulationActive FilteringActive Front-end ConvertersActive Harmonic FilteringActive Power FilterFilteringHarmonic DistortionHarmonic EffectsHarmonic Reduction
The effect of the dc-link voltage on the compensation characteristics of a shunt active filter is studied focusing on 5/sup th/ negative and 7/sup th/ positive harmonic sequences. It is shown that the type of the harmonic load has a great impact on the required dc-link voltage. According to theoretical derivation there exist harmonic current sequence pairs yielding the minimum dc-link voltage requirement. Analytical equations concerning the 5/sup th/ negative and the 7/sup th/ positive harmonic sequences are proposed. Theoretical results are confirmed with measurements using a 19 kVA active front-end converter with active filtering capabilities.
6
Flux-based active filter controller
Subhashish Bhattacharya, André Veltman, D.M. Divan et al. · IEEE Transactions on Industry Applications · 1996 · 155 citations · Full text