PubMed · 2009 · 26 citations · 0 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryDiagnostic ImagingDiagnostic RadiologyOrthopedicsAnkle Radiographic AnatomyImaging AssessmentLower Limb AlignmentOrthopedic ImagingTendon ImagingAnatomical StructureArticular AlignmentDistal Tibial AnatomyPalpable Anatomical LandmarksTibial Landmarks
We studied the accuracy of using the tibialis anterior tendon (TAT) as a distal landmark for extramedullary alignment in total knee arthroplasty. Forty-five consecutive ankle magnetic resonance imaging scans were reviewed. On the computerized images, a digital ruler was used to measure the distance from the midpoint of the distal tibia (point M) to the TAT. Mean distance was 1.89 mm; range was 0 to 4.5 mm (95% confidence interval, 1.45-2.33). For 7 (15.6%) of the 45 scans, the distance was 0 mm. On 38 scans (84.4%), the TAT was within 2 mm of point M. The TAT is an easily palpable fixed anatomical structure that corresponds very closely to the midpoint of the distal tibia.