Initial experience with technetium-99m HM-PAO brain SPECT.

I. Podreka, E. Suess, Georg Goldenberg, M. Steiner, Thomas Brücke, Ch. Müller, Wilfried Lang, R.D. Neirinckx, L. Deecke

PubMed · 1987 · 203 citations · 16 references

Concepts

TL;DR

Technetium‑99m hexamethylpropyleneamineoxime brain SPECT was performed with a dual‑head rotating camera, yielding normal tracer distribution in 11 healthy volunteers and enabling assessment of 83 patients with cerebral vascular disease, epilepsy, extrapyramidal disorders, dementia, headache, and psychiatric disorders. The scans showed stable gray/white matter ratios (1.97–2.1) and a significant increase in left inferior occipital tracer uptake during visual imagery, supporting the utility of [99mTc]HM‑PAO SPECT for detecting both pathological and physiological brain changes.

Abstract

Technetium-99m hexamethylpropyleneamineoxime ([99mTc]HM-PAO) brain single photon emission computed tomography (SPECT) was performed with a dual head rotating scintillation camera. Normal tracer distribution and side/side differences of counting rates were obtained in 11 healthy volunteers. Almost stable gray/white matter ratios were found (1.97-2.1) in one normal subject during 2 hr after tracer administration. Eighty-three investigated patients had the following diagnoses (in parentheses is percent of positive findings in each group): cerebral vascular disease 18 (94.4%), epilepsy 23 (82.6%), extrapyramidal disorders 8 (100%), dementia 12 (100%), headache 11 (63.6%), psychiatric disorders 11 (27.3%). In addition, SPECT was performed in 28 male volunteers during motor or visual imagery tasks and a significant increase (p = 0.035) of relative tracer deposition was observed in the left inferior occipital region during visual imagery when compared with motor imagery. The results indicate that [99mTc]HM-PAO SPECT is valuable for demonstrating pathologic and physiologic changes of the brain.

References

16