PubMed · 1997 · 61 citations · 12 references
DentistryDesignAdditive ManufacturingMechanical Behavior Of MaterialsTypographyAppearance EvaluationCastingCasting ProceduresDigital Impression TechniquesGypsum MaterialsImpression MaterialsDimensional StabilityGypsum CastingLinear StabilityLinear Stability Analysis
This study examined the linear dimensional stability of nonaqueous elastomeric impressions made from stock and custom trays by measuring casts derived from those impressions at 1 hour, 1 day, and 1 week. There was a small statistical difference among casts produced from stock versus custom trays compared to the master model. However, there was no significant difference in casts produced from impressions poured at 1 hour, 1 day, and 1 week. A custom tray with a 2.0 to 2.5 mm tray spacing had the least amount of variation, yet the differences between custom and stock trays may not be clinically significant.
12