A comparison of several system identification methods with application to power systems

B.J. Bujanowski, John W. Pierre, Steven Hietpas, Tom Sharpe, D.A. Pierre

2002 · 16 citations · 8 references

Concepts

Abstract

This paper presents a survey of recent advances in system transfer function identification with applications to power systems. Three different identification algorithms were analyzed; the Prony method, a direct ARMA method, and a State Space method. Although all of these methods use input and output data, there are features that make the methods distinctly different and difficult to compare directly; the merits of each are discussed. Simulation examples are given comparing the performance of the methods.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

8