Respiratory Care · 2008 · 66 citations · 16 references
MedicineClinical SciencesInternal MedicineHealth AssessmentPulmonary Function TestingPulmonologyChronic Obstructive Pulmonary DiseaseObstructive Lung DiseasePulmonary Function AssessmentPulmonary Function Test Quality ControlRespiratory AssessmentRespiratory DiseaseChronic Obstructive Pulmonary Disease SpirometryQuality Control System DesignSpirometric InterpretationSpirometrySpirometry Quality Assurance
UNLABELLED: We report the characteristics of a centralized spirometry quality-control program developed for a population-based survey of the prevalence of chronic obstructive pulmonary disease in 5 cities: São Paulo, Brazil; México City, México; Montevideo, Uruguay; Santiago, Chile; and Caracas, Venezuela (the Latin American Project for the Investigation of Obstructive Lung Diseases [PLATINO]). METHODS: We developed and used a 3-level quality-control system. Level 1: The spirometer used in the survey (EasyOne), gives quality-control messages to the user/clinician. All the spirometry technicians were trained by the same team, with the aim of meeting what became the 2005 spirometry quality criteria of the American Thoracic Society/European Respiratory Society (ATS/ERS). Level 2: In each of the 5 cities a local supervisor identified poor-quality spirometries that needed to be repeated. Level 3: Once a week during the survey, all spirometry results were sent via e-mail to the study's quality-control center in México City for review and feedback. RESULTS: In the overall totals at the end of the study, 94% of the 5,315 subjects had spirometries that met the 1994 ATS quality criteria, and 89% met the 2005 ATS/ERS criteria. In their overall totals at the end of the study, 90% of the 64 spirometry technicians were successful in getting 86% of their subjects to meet the 1994 ATS criteria, and got 75% of their subjects to meet the 2005 ATS/ERS criteria. In the first 10 subjects they tested, 90% of the 64 spirometry technicians were successful in getting 70% of their subjects to meet the 1994 ATS criteria, and got 60% of their subjects to meet the 2005 ATS/ERS criteria. CONCLUSIONS: Standardization of equipment, training, and supervision of spirometry is essential in a multinational spirometry survey. Centralized quality control can be done via e-mail with good reliability and low cost.
16
Martin R. Miller, J. Hankinson, Vito Brusasco et al. · European Respiratory Journal · 2005 · 15.7K citations · Full text
Multilevel and Longitudinal Modeling Using Stata
Biometrics · 2006 · 4.3K citations