Clinical Implant Dentistry and Related Research · 2014 · 17 citations · 23 references
DentistryImplant DentistryImplant ProsthodonticsImplant SurgeryMaxillofacial ProsthodonticsImmediate Implant LoadingPrimary StabilityBiomechanics Of Dental ImplantsDental ImplantsImplant StabilityPrimary Stability PredictionReceiver Operating Characteristic AnalysisResonance AnalysisStability ParametersTorque
BACKGROUND: To assess the suitability of dental implants for immediate loading, primary stability is usually evaluated intraoperatively. PURPOSE: This retrospective study aimed to assess the suitability of three stability parameters - namely, insertion torque (IT), implant stability quotient (ISQ; measured by resonance frequency analysis), and Periotest (PT) values - as potential predictors for the risk of nonosseointegration of immediately loaded splinted implants. The stability parameters were routinely collected under immediate loading. MATERIALS AND METHODS: Nineteen patients with 11 edentulous and 8 partially edentulous maxillae were treated with 105 dental implants, which were immediately loaded using temporary fixed dentures. The IT results, PT values, and ISQ results were recorded. Receiver operating characteristic analysis was performed to assess the quality of each parameter as a diagnostic test. RESULTS: After a 3-month observation period, 11 implants in four patients were not osseointegrated. The IT and ISQ (IT 25.0 ± 12.5 Ncm and 8.4 ± 2.3 Ncm; PT -1.5 ± 3.0 and +2.7 ± 3.0; and ISQ 62.6 ± 6.7 and 54.7 ± 6.2) differed significantly between the osseointegrated and failed implants (p < .005). The IT showed the greatest specificity at a sensitivity of 1 and the greatest area under the curve (AUC; 0.929), followed by the PT value (AUC = 0.836) and ISQ (AUC = 0.811). CONCLUSIONS: Among the intraoperative parameters analyzed, IT showed the highest specificity at a high sensitivity of 1. Therefore, the IT can be considered the most valid prognostic factor for osseointegration of immediately loaded splinted dental implants.
23
Clinical evaluation of small-diameter ITI implants: a prospective study.
Barbara Zinsli, Tanja Sägesser, Ernoe Mericske et al. · PubMed · 2004 · 262 citations
Pär‐Olov Östman, Mats Hellman, Lars Sennerby · Clinical Implant Dentistry and Related Research · 2005 · 245 citations
Methods used to assess implant stability: current status.
Mihoko Atsumi, Hom‐Lay Wang · PubMed · 2007 · 240 citations
Dentistry, Dental Biomaterials Science, Implant Dentistry +14