Publication | Closed Access
On-line MCSA to diagnose shorted turns in low voltage stator windings of 3-phase induction motors prior to failure
136
Citations
15
References
2002
Year
Unknown Venue
Experimental ResultsShorted TurnsCondition MonitoringElectric MachineOn-line McsaThree-phase Induction MotorsMotor DriveIndustrial MotorsElectrical Drive3-Phase Induction Motors
This paper focuses on experimental results to prove that motor current signature analysis (MCSA) can diagnose shorted turns in low voltage stator windings of three-phase induction motors. The diagnostic strategy is presented and variables that influence the diagnosis are discussed. Current spectra from motors with short-circuited turns (with and without short circuit current limiting resistors) are presented and fully analysed. Results from motors tested to failure are reported. The results in this paper were from industrial motors of different pole numbers with concentric and lap wound winding designs. Since stator failures account for a high percentage of failures, the results are particularly relevant to industry.