DentistryDental Biomaterials ScienceDental Materials ScienceDental MaterialsProsthodontic MaterialsSurface Properties Of Dental MaterialsImplant MaterialsImplant Site AssessmentSurface Modification Of ImplantsDental ImplantsEnergy Dispersive X-ray SpectroscopyEnergy-dispersive X-ray SpectroscopyEtchingImplant Surface RoughnessRemoval TorqueSurface CompositionTorque
OBJECTIVE: To study the composition, surface characteristics and response to removal torque of an implant surface subjected to hydrofluoric acid etching and posterior passivating with hydrofluoric and nitric acid. STUDY DESIGN: Twelve implants were initially selected and their physico-chemical characteristics were evaluated by means of energy-dispersive X-rays (EDS), scanning electron microscopy (SEM) and photoelectron spectroscopy (XPS). In addition, 24 implants - 12 measuring 8 mm and 12 measuring 10 mm in length - were implanted in 6 Beagle dogs. Twelve implants were removed after a recovery period of 6 weeks, followed by removal of the remaining 12 implants after 12 weeks, using a torque calibrator (Gauge Tonichi model BGT150CN-S) with a force registry range of 0-150 Ncm. RESULTS: EDS analysis of the surface chemical composition only revealed the presence of titanium in the etched surfaces. In the same way as with the surfaces of other dental implants, XPS analysis revealed traces of other elements present in the surface, fundamentally carbon. Following dual acid etching, the surface showed the roughness resulting from acid action, with a morphology that proved to be quite homogeneous. The roughness values obtained exceeded 1 mm. The mean removal torque values after 6 weeks were 79.7 Ncm for the 8 mm implants and 115 Ncm for the 10 mm implants. After 12 weeks, these values increased to 101.2 Ncm and 139.7 Ncm, respectively. CONCLUSIONS: Hydrofluoric and nitric acid etching affords optimum surface characteristics comparable to those of other surfaces. The recorded removal torque values raise the possibility of human clinical application for early or immediate loading procedures.
13
J. Y. Martin, Zvi Schwartz, Thomas W. Hummert et al. · Journal of Biomedical Materials Research · 1995 · 1.1K citations
Roger Watson · British Journal of Oral and Maxillofacial Surgery · 1985 · 674 citations
Removal torque values of titanium implants in the maxilla of miniature pigs.
Daniel Buser, Thomas Nydegger, Hans Peter Hirt et al. · PubMed · 1998 · 250 citations
Medicine, Implant Dentistry, Surgery +14