Applicability of Chemical Cleaning Process to Steam Generator Secondary Side, (II)

Hirotaka Kawamura, Kazutoshi FUJIWARA, Hiromi Kanbe, Hideo Hirano, Hideki Takiguchi, Kouji YOSHINO, Shuuichi Yamamoto, Toshio Shibata, Kenkichi Ishigure

Journal of Nuclear Science and Technology · 2005 · 14 citations · 2 references

Concepts

Abstract

The application of a chemical cleaning process to dissolve and remove scale and sludge by chemicals is being planned for Japanese pressurized water reactor (PWR) plants in order to maintain a high heat transfer condition and to prevent the SG tubing degradation. In this paper, the effectiveness of the EPRI process and the KWU process to maintain integrity of SG tubing were investigated under accelerated IGSCC conditions. IGSCC susceptibility and propagation ratio of degraded SG tubing with chemical cleaning, were the same as those of tubing not subjected to the chemical cleaning process. Neither the EPRI nor the KWU process adversely affected tubing integrity.

References

2