Respiratory Care · 2006 · 26 citations · 23 references
MedicineRespiratory TherapyPulmonologyVentilationVentilator ManagementAirway ManagementBreathing SupportMechanical VentilationRespiratory Monitoring InstrumentsVentilation RequirementsVentilatory SupportAerosol Delivery During Mechanical VentilationAerosol Delivery EfficiencyAerosol Delivery SystemsFractional Inspired OxygenLower Airway ObstructionMechanical Ventilation ManagementTidal Volume SettingsTidal Volume Titration
The indications for heliox during mechanical ventilation are lower-airway obstruction, especially with hypercarbia; need to enhance aerosol delivery to lung periphery; and need to facilitate weaning from mechanical ventilation. Certain ventilators perform relatively well with heliox and are not substantially affected by it. It is preferable to connect the heliox to the air inlet of the ventilator, because this results in more consistent delivery of oxygen and tidal volume. When administering heliox, pay close attention and directly monitor the actual tidal volume and fraction of inspired oxygen.
23
Heliox Therapy in Acute Severe Asthma
Jonathan Kass, Richard J. Castriotta · CHEST Journal · 1995 · 142 citations
The Effect of Heliox on Nebulizer Function Using a β-Agonist Bronchodilator
Dean Hess, Frank L. Acosta, R Ritz et al. · CHEST Journal · 1999 · 139 citations