PubMed · 1994 · 49 citations · 0 references
DentistryDental HygieneImplant DentistryDental MaterialsMechanical Properties Of Dental MaterialsSurface Properties Of Dental MaterialsAbutment DesignSurface Finish QualitySurface HardnessImplant Abutment MaterialsImplant Surface RoughnessSurface Finish Of AbutmentsSurface Roughness ParametersTitanium AbutmentsTitanium Implant MaterialsTitanium MaterialsTooth Surface Hardness
Clinical studies have reported a positive correlation between the surface roughness of teeth or implants and the rate of supragingival and subgingival plaque maturation. This study compared the surface characteristics of abutments from different implant systems (Astra Tech, Bonefit, Brånemark, Core-Vent, IMZ, and Steri-Oss). For each system, two abutments were examined for surface roughness and surface hardness. The latter served as an indicator for resistance against roughening during professional or habitual oral hygiene procedures. The Ra values (in microns) of the tested abutments were: Steri-Oss, 0.10; IMZ, 0.14; Brånemark, 0.21; Bonefit, 0.23; Astra Tech, 0.27; and Core-Vent, 0.30. The Vickers hardness scores (in VHN) were: Brånemark, 154; IMZ, 208; Astra Tech, 258; Bonefit, 292; Core-Vent, 304; and Steri-Oss, 340. In comparison to most metallographically polished composites, titanium abutments showed a higher initial surface roughness and a slightly higher surface hardness. This may explain, besides the known high surface free energy of titanium, rapid plaque growth on these abutments.