Characterisation of voltage shapes acting on the insulation of rotating machines supplied by inverters

J.P. Bellomo, Thierry Lebey, J.M. Oraison, F. Peltier

2002 · 14 citations · 6 references

Concepts

Abstract

Use of frequency inverters for supply of electrical rotating machine is becoming more usual, particularly for applications needing a rotating speed variation. New semiconductors, like Gate Turn-off thyristor (GTO) or Insulated Gate Bipolar Transistor (IGBT), can work at very high frequency, up to 10 kHz, with very short rise times down to less than 0.1 /spl mu/s. In order to study the ageing associated with these voltage shapes, we have first tried to characterise them. The inverter is a Pulse Width Modulated one (PWM) feeding a 220 V squirrel cage induction motor modified to observe the propagation of voltage shape in the winding. This adaptation results in 36 shielded coaxial wires distributed on the 6 coils and the 17 turns. Turn-to-turn and turn-to-ground voltages are recorded. A spectral analysis shows that the driving frequency is the main frequency propagating in the winding with no attenuation. On the other hand, the motor input turn-to-turn voltages show very short rise time voltage waves (typically 2000V//spl mu/s) which are very attenuated and a delay growing during propagation in the winding. Moreover, on the input coils, high frequency oscillations and overvoltages are observed, depending on supply cable length.< <ETX xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">&gt;</ETX>

References

6