Evaluation rhythm problems in unexplained syncope etiology with implantable loop recorder

Yakup Ergül, İbrahim Cansaran Tanıdır, İsa Özyılmaz, Celal Akdeniz, Volkan Tuzcu

Pediatrics International · 2014 · 18 citations · 17 references

Concepts

Abstract

BACKGROUND: Syncope is a frequent complaint in children and adolescents and may be a significant sign of serious pathology. Although patient history, family history, and physical examination are sufficient to reach a diagnosis in most cases of syncope, the cause of syncope still cannot be determined after initial investigation in one-third to half of all patients. The aim of this study was to evaluate the diagnostic yield of implantable loop recorder (ILR) in children with unexplained syncope. METHODS: A retrospective review was carried out of clinical data, indications, findings, and a final management strategy in patients who underwent ILR implantation. RESULTS: A total of 12 patients with a mean age of 9.4 ± 4.5 years underwent ILR (Reveal Plus; Medtronic) implantation. ILR implantation indication was syncope in all of the patients. Family history, routine cardiac assessment, including resting 12-lead electrocardiogram, transthoracic echocardiography, 24 h Holter recording, and event recorder findings, were normal with the exception of one patient with (previously corrected) tetralogy of Fallot. After an average of 20 months (range, 1-36 months), six patients developed symptoms. ILR memory showed torsades de pointes-ventricular fibrillation (n = 3), catecholaminergic polymorphic ventricular tachycardia (n = 1), asystole and ventricular tachycardia (n = 1), and normal sinus rhythm (n = 1). At the time of writing six patients were still in follow up with no symptoms after an average of 25.2 months. CONCLUSION: Implantable loop recorder plays an important role in the diagnosis of life-threatening arrhythmias in which syncope is otherwise unexplained. ILR implantation should be remembered in children whose symptoms are strongly correlated with rhythm disturbances.

References

17

ACC/AHA clinical competence statement on electrocardiography and ambulatory electrocardiography41This document was approved by the American College of Cardiology Board of Trustees in November 2001 and the American Heart Association Science Advisory and Coordinating Committee in August 2001.42When citing this document, the American College of Cardiology and the American Heart Association would appreciate the following citation format: Kadish AH, Buxton AE, Kennedy HL, Knight BP, Mason JW, Schuger CD, Tracy CM. ACC/AHA clinical competence statement on electrocardiography and ambulatory electrocardiography: a report of the American College of Cardiology/American Heart Association/American College of Physicians-American Society of Internal Medicine Task Force on Clinical Competence (ACC/AHA Committee to Develop a Clinical Competence Statement on Electrocardiography and Ambulatory Electrocardiography); J Am Coll Cardiol 2001;38:2091–100.43This document is available on the World Wide Web sites of the American College of Cardiology (www.acc.org) and the American Heart Association (www.americanheart.org). Reprints of this document may be purchased for $5.00 each by calling 1-800-253-4636 or by writing to the American College of Cardiology, Educational Services, 9111 Old Georgetown Road, Bethesda, Maryland 20814-1699.44© 2001 by the American College of Cardiology and American Heart Association, Inc.

Alan H. Kadish, Alfred E. Buxton, Harold L. Kennedy et al. · Journal of the American College of Cardiology · 2001 · 241 citations

, , +13