Journal of Applied Physiology · 1989 · 238 citations · 0 references
Life SciencesPhysiologyVeterinary PhysiologyMechanobiologyMotor ControlVentilationMaximal Voluntary VentilationMechanical VentilationPulmonary MechanicsRespiratory BiomechanicsRespiratory PhysiologyRespiratory System ModelingDiaphragm MechanicsDiaphragm Mechanics ModelingPhrenic Nerve StimulationRespiratory Muscle MechanicsRespiratory System MechanicsTransdiaphragmatic PressureVentilatory DynamicsVentilatory Mechanics
The forces generated by the cat diaphragm (DIA) during different ventilatory and nonventilatory behaviors were determined by measuring transdiaphragmatic pressures (Pdi). The Pdi generated during eupnea was only approximately 12% of the maximum Pdi (Pdimax) generated by bilateral phrenic nerve stimulation. When the animals breathed a gas mixture of 10% O2 and 5% CO2, the Pdi increased to approximately 28% of Pdimax. During total airway occlusion, the Pdi generated by the diaphragm increased to approximately 49% of Pdimax. Only during the gag reflex and sneezing did Pdi reach maximal levels. A model for diaphragm motor unit recruitment during these different behaviors was presented based on the proportion of different motor unit types within the diaphragm, the relative tetanic tensions produced by each unit type, and the assumption of an orderly pattern of motor unit recruitment.