Dissimilar-weld failure analysis and development program

Declan Roberts, R.H. Ryder, H.J. Grunloh, B.E. Thurgood

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1989 · 13 citations · 0 references

Concepts

Abstract

As a result of the work performed under RP 1874-1, the factors influencing the performance of dissimilar metal welds (DMWs) in elevated temperature power plant boiler service have been defined. Details of the results are given in other volumes of this report series. In this volume, design and procedure guidelines for improving DMW performance are provided. DMW life can be extended by: locating DMWs such that service conditions are conducive to long life; such locations may be identified by the use of the computerized analytical program PODIS, developed under RP 1874; using preferred weld filler metals; and using specific weld configurations. Details of each of these approaches are described herein. 5 figs., 2 tabs.